Automation Systems

Distribution, Acquisition, Communication and Control providing; real time monitoring, control, measurement, data storagae, collection and custody transfer.

 


Gas Pilot Operated Regulators

Pilot operated to regulate upstream, downstream, and differential pressure ranging from vacuum to 500 psig in pneumatic systems.

 


High Pressure Level Controls

Float or pressure actuated pilots send a pneumatic signal to control liquid level in vessels up to 4000 psig.

 


Lever Operated Valves and Controls

Mechanical oil valves and float opening covers for direct operated control of oil or water levels in tanks or pressure vessels up to 500 psig.

 


Dump Valves

Heater Treater or Salt Water Disposal Valves, balanced lever operated oil or water dump valves to control liquid levels in vessels up to 125 psig.

 


Control Valves

High Pressure Manual, Electronic and Diaphragm operated gas motor valves. 10 to 30 psig actuator signal to control up to 4000 psig.

 


Low Pressure Valves

Diaphragm operated gas valves. 10 to 30 psig actuator signal for control in systems up to 500 psig.

 


Balanced Valves

Diaphragm or Piston balanced, diaphragm operated oil valves. 10 to 100 psig signal for control is systems up to 400 psig.

 


3 Way Valves

Diaphragm or Piston balanced, diaphragm operated 3 way and diverter valves. 10 to 30 psig actuator signal for test sampling or diverter control in systems up to 3000 psig

 


Low Pressure Floatless Level Controls

Differential pilot senses difference of gas and fluid pressure to actuate diaphragm operated motor valves. Control 0 to 100 feet of water in vessels to 125 psig.

 


Glycol Pumps

Utilize wet glycol absorber pressure to pump glycol in dehydrators and gas amine desulphurizers.

 


Temperature Controllers

Sense temperature to send a pneumatic actuator signal to control 30°F to 750°F in systems up to 7000 psig.

 


Pneumatic Pilots & Relays

0 to 30 psig signal pilots, 0 to 1500 psig control pilots. Available in All Steel, some available in Ductile Iron.

 


Pneumatic Control Pilots

Pneumatic pressure pilot sends 20 psig actuator signal to control diaphragm operated motor valves where sensed pressure ranges from 50 to 1500 psig.

 


Pressure Differential Controller

Differential pilot send pneumatic actuator signal to control flow across meter runs by positioning a pressure opening control valve in systems up to 4000 psig.

     
     